LAM XVME-560 驱动板

 LAM | 2024-01-15 10:51:00| 小编  提示:点击图片可以放大

LAM XVME-560 驱动板

产品概述:

XVME-560离散输出配置设置。当为false时,只有关闭才会激活离散输出。当为true时,任何报警或停机条件都将激活离散输出。离散输出包括Runenable[Run/Enable]dflt=true(false,true)(此参数仅适用于ProAct软件2.10版或更高版本)(检查服务:单元状态下的版本号:)当设置为true时,当Run Enable离散输入(低功率待机模式)触点打开时,状态输出也将打开。当设置为false时,运行启用(低功率待机模式)触点的条件不会影响状态输出。Run Enable–Closed to Run dflt=true(false,true)(此参数仅适用于ProAct Software Version 2.20特殊固件XVME-560零件号5418-2590)(检查“服务:单元状态”下的版本号:)设置为true时,XVME-560运行启用触点将在运行模式下闭合,在低功率待机模式下打开。当设置为false时,运行启用触点将在运行模式下打开,在低功率待机模式下关闭。停机操作dflt=3(1,3)选择检测到停机条件时要执行的操作。选择选项:1=最小,2=最大,3=Pwr向下。(请参阅停机说明待定)。温度报警SP(°C)dflt=95°C(50150)高温报警设定点,单位为摄氏度。此警报基于内部电子设备温度。有关详细信息,请参阅报警部分。温度报警延迟(秒)dflt=1秒(0,10)高温报警延迟(以秒为单位)。

XVME-560 70560-001.jpg


XVME-560执行机构类型dflt=3(1=ProAct1,2=ProAct2,…4=ProAct4)ProAct执行机构类型配置。这被设置为适当的ProAct致动器(例如,ProAct Model 4将被设置为“4”)。执行机构CCW方向dflt=false(false=CW,true=CCW)ProAct执行机构方向配置——顺时针与逆时针——从执行机构的轴端看。执行机构惯性设置dflt=0(范围0–25)执行机构/阀门惯性设置。此设置适用于惯性高于或低于默认值的系统,如轴移动过大所示。XVME-560零(0)设置基本上适用于未连接的轴,而增加设置意味着系统中的惯性更高。该参数也可以在服务模式下进行调整和测试——有关详细信息,请参阅调整用户停止部分中的调整和测试致动器动态(有关更多详细信息,见图9-8)。高摩擦系统dflt=false(false,true)内部扰动观测器控制器(dobs)启用命令。通常设置为false,仅在高摩擦系统中需要。XVME-560该参数也可以在服务模式下进行调整,以确定是否需要它——有关详细信息,请参阅调整用户停止部分中的调整和测试致动器动态(有关更多详细信息,见图9-8)。


XVME-560 70560-001(1).jpg


  Like the Standard version, the Professional version of Watch Window software can be downloaded and  This site can also be used to obtain license authorizations

Entering Configure Mode Select the Configure Mode tab sheet and shut down the driver by setting the Shutdown Command value to ‘true’ or by opening the Low Power Standby Mode discrete input.XVME-560 Enter the appropriate configure mode Password (1113) and either select ‘ENTER’ or click on the equals (=) box to the right of the password box. The ‘Enabled’ field will display ‘true’ if the Configure Mode has been successfully entered. Configure the unit by setting the Unit Setup and Demand Setup parameters to the application specific values. Refer to the Configure Mode Details section of the manual for details on these settings.XVME-560 As changes are made to Configure and Service mode parameters, they are automatically saved into non-volatile memory—no special ‘save’ command is required. XVME-560Configuring the Unit (Configure Mode parameters) Refer to the information provided later in this chapter for details on the Configure Mode parameters. A program summary worksheet is provided in the Appendix as an overview of all software settings in the ProAct control. 


1.15-1.png


Watch Window Standard and Professional There are two versions of the Watch Window software, Standard and Professional. Watch Window Standard XVME-560is provided with the ProAct control as a Service Tool for Configuration, Tuning, and Monitoring. Watch Window Standard supports only Service and Configure modes. The Standard version of Watch Window will not display Factory Calibration, Test, and Debug mode values. Only the professional version has this capability. Watch Window Professional is available as a purchased upgrade, but is not required for this product. In addition to providing Factory Calibration,XVME-560 Test, and Debug mode access, the Professional version provides software download capabilities for new or revised software versions.XVME-560




图片1_副本.png


 

The Inspector can have its configuration saved and restored. The Inspector can be closed by using the Main Window or by clicking the standard windows close button. Watch Window Decimal Places The number of digits displayed after the decimal place displayed in Watch Window can be adjusted from the Precision setting under the Watch Window Options menu. Watch Window Help More help on using Watch Window is available and included with the installation of the Watch XVME-560product. Watch XVME-560Help can be accessed from the Watch Window ‘Contents’ drop-down window selection under the Help menu located on the Main Window. Software Version Identification The Watch Window software version can found by selecting ‘About’ under the Help menu. The ProAct software version information can be found by selecting ‘Properties’ under the Control menu. Refer to this information in any correspondence with XVME-560