PROSOFT MVI56-MNET 伺服电机

 PROSOFT | 2024-01-18 09:13:08| 小编  提示:点击图片可以放大

PROSOFT MVI56-MNET 伺服电机

远程机架中的MVI56-MNET网桥可以连接到该机架中的ControlLogix PAC,也可以连接到远程机架的EtherNet/IP网桥、ControlNet网桥、DHRIO网桥或DH485网桥。EtherNet/IP桥接机架可以连接到CompactLogix PAC。MVI56-MNET桥接本地机架中的DHRIO桥可以直接连接到PLC 5或SLC,或者连接到远程ControlLogix机架中的另一个DHRIO电桥。远程机架中的DHRIO桥接器可以连接到该机架中的ControlLogix PAC,也可以连接到远程机架的EtherNet/IP桥接器、ControlNet桥接器、DHRIO桥或DH485桥。ControlNet网桥本地机架中的ControlNet网桥可以直接连接到PLC 5,或者连接到远程ControlLogix机架中的另一个ControlNet网桥。远程机架中的ControlNet网桥可以连接到该机架中的Control Logix PLC,也可以连接到远程机架的EtherNet/IP网桥、ControlNet网桥、MVI56-MNET网桥或MVI56-MNET网桥。MVI56-MNET桥本地机架中的DH485桥可以直接连接到SLC、MicroLogix或ControlLogix PAC,也可以连接到远程ControlLogix机架中的另一个MVI56-MNET桥。远程机架中的DH485桥接器可以连接到该机架中的ControlLogix PAC,也可以连接到远程机架的EtherNet/IP桥接器、ControlNet桥接器、DHRIO桥接器或DH485桥接。ControlLogix-PLC本地机架中的ControlLogix-PAC可以通过桥接模块连接到PLC 5、SLC、MicroLogix或ControlLogix-PC,或者连接到远程ControlLogix机架中的另一个ControlLogix-PIC。远程机架中的ControlLogix PAC可以连接到该机架中的Control Logix PAC,也可以连接到远程机架的EtherNet/IP网桥、ControlNet网桥、MVI56-MNET网桥或MVI56-MNET网桥。




 MVI56-MNET 单击“删除”按钮以删除选定的对象。或者,选择一个对象,然后按[DEL]键删除(永久删除)该对象。· Timeout指定与设备通信时使用的超时值(以毫秒为单位)。· 寻址信息包含对网络上或设备所在机架中的设备进行寻址的信息。根据接口类型和设备类型,也可以使用其他参数。下表介绍了每种接口/设备类型的寻址参数。参数描述接口寻址被指定为插槽编号。MVI56-MNET网桥寻址被指定为节点号。MVI56-MNET网桥寻址被指定为通道和节点号。MVI56-MNET桥接寻址指定为通道和节点编号桥接(ControlLogix背板)设备配置在本地机架的桥接接口下。在配置编辑器树中选择DEVICES节点。内容窗格将显示一个表,其中包含为该网桥定义的所有设备。ILX56-MM支持以下桥接器:· MVI56-MNET网桥(第35页)· DHRIO大桥(第35页)· DH485桥接器(第37页)· MVI56-MNET桥接(第36页)™ EtherNet/IP网桥本地机架中的1756 EtherNet/IP网桥可以直接连接到PLC 5、SLC或MicroLogix。EtherNet/IP网桥也可以连接到远程机架中的另一个EtherNet/IP网桥或CompactLogix PAC。




MVI56-MNET For example, sequential reads of Status Bits 10001 and 10003 will result in two read request messages. 1 Scattered Coil (0x0000) and Status Bit (1x0000) read requests with up to a 1 byte (8 bit) gap may be combined in a single request message. For example, sequential reads of 10001 and 10003 will result in a single request message with 10002 being discarded.MVI56-MNET Scattered sequential Holding (4x0000) and Input (3x0000) register accesses must be contained or exactly adjacent. 8 Scattered sequential reg/coil read requests that have up to an 8 byte gap may be combined in the same read request message. 16 Scattered sequential reg/coil read requests that have up to a 16 byte gap may be combined in the same read request message. 32 Scattered sequential reg/coil read requests that have up to a 32 byte gap may be combined in the same read request message. 64 Scattered sequential reg/coil read requests that have up to a 64 byte gap may be combined in the same read request message.MVI56-MNET 128 Scattered sequential reg/coil read requests that have up to a 128 byte gap may be combined in the same read request message.Tags refer to individual data objects in the controllers that can be transferred to another controller.

 



 Each Device has the following unique parameters. Parameter Description Node Address The Modbus Node Address of the slave device to connect to the module. If you are connecting to a Quantum PLC via a bridge,MVI56-MNET enter the Modbus node address of the device connect to the module. If you are directly connecting to a Quantum PLC, set this to 0. Message Idle Time The idle time between messages in milliseconds. Range is 0 to 50. Register Addressing Type The type of addressing used to access Long Integers and Floating Point data, where: Normal Longs/Floats occupy two 16-bit registers. Register order is normal. Modicon Longs/Floats occupy two 16-bit registers. Register addressing order is WORD reversed.MVI56-MNET 32-bit Longs/Floats occupy one 32-bit register. Maximum Data Bytes The maximum number of register or coil data bytes contained in a single MODBUS message body.MVI56-MNET Valid options are 4, 32, 64, 128, 192, and 244. If an array tag is larger than this value, multiple messages may be used to complete the data access.No gaps are allowed in the reg/coil data block. Only sequential contiguous reg/coil read requests may be combined in a request message.MVI56-MNET

NeoImage_副本.jpg


Each Interface has a unique Name,MVI56-MNET IP address, Remote Rack Number, Remote Slot Number, Retries, and Timeout.The Timeout specifies the timeout value in milliseconds to be used in communicating with the device. The addressing information: IP address, Remote Rack Number, and Remote Slot Number contains information to address the device on the S7 Industrial Ethernet network.MVI56-MNET 3.2.3 Modbus TCP/IP (Schneider Electric Quantum PLCs) An Interface defined as Modbus TCP/IP will contain a Devices node under it in the Configuration Editor tree.MVI56-MNETEach Devices node will contain a Tags node in the Configuration Editor tree. The Tags node contains all the Tags referenced for that controller.MVI56-MNET