使用罗克韦尔自动化推荐的相同技术来拆卸和安装ControlLogix模块。您可以在机箱通电和系统运行时安装或卸下ControlLogix系统组件。但是,请注意以下警告。警告:当背板电源打开时插入或卸下模块时,可能会发生电弧。电弧可能会导致人身伤害或财产损失,原因是:向系统的执行器发送错误信号,导致机器意外移动或失去过程控制,导致危险环境中发生爆炸。在继续操作之前,请确认电源已断开或该区域无危险。反复的电弧会导致模块及其配对连接器上的触点过度磨损。触点磨损可能会产生电阻,从而影响模块的工作。1将模块与顶部和底部导轨对齐,然后将其滑入机架,直到模块牢固地靠在背板连接器上。·
一台运行受支持版本的Microsoft Windows的个人计算机,带有Microsoft Internet Explorer版本7(或更高版本)、RSLogix 5000、RSLinx和以太网端口一个带有1756-ENBT和ILX56-MM模块的ControlLogix处理器一个CompactLogix处理器将ControlLogix机架连接到CompackLogix机架的以太网模块背面有一个设置跳线,标记为J1。设置跳线充当模块固件的“写入保护”。在“写保护”模式下,安装引脚未连接,模块的固件无法覆盖。下图显示了设置跳线关闭时的ILX56-MM跳线配置。如果您尚未安装和配置ControlLogix处理器和电源,请在安装ILX56-MM模块之前进行安装和配置。有关安装说明,请参阅罗克韦尔自动化产品文档。警告:安装此或任何其他电子设备时,必须遵守所有安全说明。不遵守安全程序可能导致硬件或数据损坏,甚至人员重伤或死亡。在安装或维修设备之前,请参阅计划连接的每个设备的文档,以验证是否有适当的安全程序。检查跳线的位置后,将ILX56-MM插入ControlLogix机箱。
An electrical arc can cause personal injury or property damage by: ƒ sending an erroneous signal to your system’s actuators causing unintended machine motion or loss of process control ƒ causing an explosion in a hazardous environment Verify that power is removed or the area is non-hazardous before proceeding. Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance that can affect module operation. 1 Align the module with the top and bottom guides, and then slide it into the rack until the module is firmly against the backplane connector.
Failure to follow safety procedures could result in damage to hardware or data, or even serious injury or death to personnel. Refer to the documentation for each device you plan to connect to verify that suitable safety procedures are in place before installing or servicing the device. After you have checked the placement of the jumper, insert ILX56-MM into the ControlLogix chassis. Use the same technique recommended by Rockwell Automation to remove and install ControlLogix modules. You can install or remove ControlLogix system components while chassis power is applied and the system is operating. However, please note the following warning. Warning: When you insert or remove the module while backplane power is on, an electrical arc can occur.
A Personal Computer running a supported version of Microsoft Windows, with Microsoft Internet Explorer version 7 (or higher), RSLogix 5000, RSLinx, and an Ethernet port ƒ A ControlLogix processor with 1756-ENBT and ILX56-MM modules ƒ A CompactLogix processor ƒ An Ethernet network connecting the ControlLogix rack to the CompactLogix rackThere is one Setup Jumper located on the back of the module, labeled J1. The Setup Jumper acts as "write protection" for the module's firmware. In "write protected" mode, the Setup pins are not connected, and the module's firmware cannot be overwritten. The following illustration shows the ILX56-MM jumper configuration, with the Setup Jumper OFF.If you have not already installed and configured your ControlLogix processor and power supply, please do so before installing the ILX56-MM module. Refer to your Rockwell Automation product documentation for installation instructions. Warning: You must follow all safety instructions when installing this or any other electronic devices.